# Awnings %% DATAVIEW_PUBLISHER: start ``` TABLE WITHOUT ID AREA + " \ "+ BuildingElement + "<br><br>" + file.link as Issue, SECTION as Description FROM "3 Resources/Issues" FLATTEN Areas as AREA FLATTEN BuildingElement as BuildingElement sort AREA ASC WHERE contains(BuildingElement,[[Awnings]]) FLATTEN list(filter(file.lists, (x) => meta(x.section).subpath = "Issue Description").text) as SECTION ``` %% | Issue | Description | | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | | [[3 Resources/Areas/Facade.md\|Facade]] \ [[3 Resources/Building Elements/Awnings.md\|Awnings]]<br><br>[[3 Resources/Issues/Access Panels to Awning Soffits are Omitted.md\|Access Panels to Awning Soffits are Omitted]] | <ul><li>From time to time, cantilevered awnings need to be inspeceted.</li><li>Access Panels or removable covers shall be provided at the base of each outrigger to allow for inspection and testing to the anchors in concrete slab edges.</li><li>The access panels shall</li></ul> | | [[3 Resources/Areas/Ground Floor.md\|Ground Floor]] \ [[3 Resources/Building Elements/Awnings.md\|Awnings]]<br><br>[[3 Resources/Issues/Access Panels to Awning Soffits are Omitted.md\|Access Panels to Awning Soffits are Omitted]] | <ul><li>From time to time, cantilevered awnings need to be inspeceted.</li><li>Access Panels or removable covers shall be provided at the base of each outrigger to allow for inspection and testing to the anchors in concrete slab edges.</li><li>The access panels shall</li></ul> | | [[3 Resources/Areas/Ground Floor.md\|Ground Floor]] \ [[3 Resources/Building Elements/Awnings.md\|Awnings]]<br><br>[[3 Resources/Issues/Kilplock Roofing is difficult to remove.md\|Kilplock Roofing is difficult to remove]] | <ul><li>Kliplock roofing profiles are difficult to remove</li><li>Subsequently future service and maintence becomes unecessarily difficult.</li><li>TrimDek roofing profiles shall be used in lieu of Kliplock profiles.</li></ul> | | [[3 Resources/Areas/Roof.md\|Roof]] \ [[3 Resources/Building Elements/Awnings.md\|Awnings]]<br><br>[[3 Resources/Issues/Box Gutters Sumps and Overflows.md\|Box Gutters Sumps and Overflows]] | <ul><li>All Box Gutters must drain to either a Sump or Rainwater Head.</li><li>All Sumps and Rainwater Heads must have an overflow.</li><li>Box Gutters, Sumps, Overflows and Rainwater heads all have very specific sizing requirements.</li><li>These areas are frequently neglected by the Stormwater Engineer and the builder and the subcontractor are left to resolve this.</li><li>This also includes Metal Awnings.</li></ul> | | [[3 Resources/Areas/Roof.md\|Roof]] \ [[3 Resources/Building Elements/Awnings.md\|Awnings]]<br><br>[[3 Resources/Issues/Kilplock Roofing is difficult to remove.md\|Kilplock Roofing is difficult to remove]] | <ul><li>Kliplock roofing profiles are difficult to remove</li><li>Subsequently future service and maintence becomes unecessarily difficult.</li><li>TrimDek roofing profiles shall be used in lieu of Kliplock profiles.</li></ul> | %% DATAVIEW_PUBLISHER: end %%