##### [[Building Elements]] # Internal Walls %% DATAVIEW_PUBLISHER: start ``` TABLE WITHOUT ID Areas + " \ "+ BuildingElement + "<br><br>" + file.link as Issue, SECTION as Description FROM "3 Resources/Issues" FLATTEN BuildingElement as BuildingElement sort AREA ASC WHERE contains(BuildingElement,[[Internal Walls]]) FLATTEN list(filter(file.lists, (x) => meta(x.section).subpath = "Issue Description").text) as SECTION ``` %% | Issue | Description | | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | | [[3 Resources/Areas/Everywhere.md\|Everywhere]] \ [[3 Resources/Building Elements/Internal Walls.md\|Internal Walls]]<br><br>[[3 Resources/Issues/Clash between Pipes, Fire Collars and Walls.md\|Clash between Pipes, Fire Collars and Walls]] | <ul><li>Fire collars to be shown on CSPs.</li><li>Min. 100mm away from Intello internal sarking to provide enough space for turning it into corners + ease of reach out behind lagged pipes with bare hands.</li><li>Update wall junctions accordingly.</li><li>This is not compliant. Fire collar should be out of finish wall zone. Show fire collars on CSPs.</li><li>Note should be added on services drawings.</li></ul> | | [[3 Resources/Areas/Everywhere.md\|Everywhere]] \ [[3 Resources/Building Elements/Internal Walls.md\|Internal Walls]]<br><br>[[3 Resources/Issues/Hebel Walls Must Be Constructed First.md\|Hebel Walls Must Be Constructed First]] | <ul><li>Walls should be constructed before services are installed.</li><li>If done in the reverse order, it is difficult perhaps impossible to properly fire-rate a penetration.</li></ul> | | [[3 Resources/Areas/Everywhere.md\|Everywhere]] \ [[3 Resources/Building Elements/Internal Walls.md\|Internal Walls]]<br><br>[[3 Resources/Issues/NBN Conduits Cast Into Slab.md\|NBN Conduits Cast Into Slab]] | <ul><li>Almost impossible to fire-seal NBN Conduits which are cast into the slab.</li><li>Instead, these should all be fire stopped at the EDB / Comms Cupboards</li></ul> | | [[3 Resources/Areas/Everywhere.md\|Everywhere]] \ [[3 Resources/Building Elements/Internal Walls.md\|Internal Walls]]<br><br>[[3 Resources/Issues/Passive Fire Documentation.md\|Passive Fire Documentation]] | <ul></ul> | | [[3 Resources/Areas/Everywhere.md\|Everywhere]] \ [[3 Resources/Building Elements/Internal Walls.md\|Internal Walls]]<br><br>[[3 Resources/Issues/Plasterboard Walls Must be Constructed First.md\|Plasterboard Walls Must be Constructed First]] | <ul><li>Walls should be constructed before services are installed.</li><li>If done in the reverse order, it is difficult perhaps impossible to properly fire-rate a penetration.</li></ul> | | [[3 Resources/Areas/Everywhere.md\|Everywhere]] \ [[3 Resources/Building Elements/Internal Walls.md\|Internal Walls]]<br><br>[[3 Resources/Issues/Poor Installation of Mastic Around Cables.md\|Poor Installation of Mastic Around Cables]] | <ul><li>Mastic around cables typically requires coning to be compliant.</li></ul> | | [[3 Resources/Areas/Everywhere.md\|Everywhere]] \ [[3 Resources/Building Elements/Internal Walls.md\|Internal Walls]]<br><br>[[3 Resources/Issues/PVC Penetrations Must Be Cored.md\|PVC Penetrations Must Be Cored]] | <ul><li>PVC Penetrations through walls must be cored.</li><li>Square cut holes are not acceptable.</li><li>These cannot be fire rated properly.</li><li>Ensure that all penetrations are round!</li></ul> | | [[3 Resources/Areas/Everywhere.md\|Everywhere]] \ [[3 Resources/Building Elements/Internal Walls.md\|Internal Walls]]<br><br>[[3 Resources/Issues/Walls in Wet Areas or Basement.md\|Walls in Wet Areas or Basement]] | <ul><li>Basements, Garbage Rooms, Service cupboards are all frequently hosed down as part of their cleaning.</li><li>If lightweight walls are installed in these areas, the plaster on the base of the wall will become damaged.</li><li>Waterproofing the base of the wall and installing a tile skirting board will protect the plaster from damage.</li></ul> | | [[3 Resources/Areas/Everywhere.md\|Everywhere]] \ [[3 Resources/Building Elements/Internal Walls.md\|Internal Walls]]<br><br>[[3 Resources/Issues/Unicollar Installation Around Pex Pipe.md\|Unicollar Installation Around Pex Pipe]] | <ul><li>Install Promat Promaseal around the 5mm gap to the pex pipe.</li><li>Install Unicollar and Grafitex inside collar - 2 fixings.</li></ul> | %% DATAVIEW_PUBLISHER: end %%