##### [[Building Elements]] # Membrane %% DATAVIEW_PUBLISHER: start ``` TABLE WITHOUT ID Areas + " \ "+ BuildingElement + "<br><br>" + file.link as Issue, SECTION as Description FROM "3 Resources/Issues" FLATTEN BuildingElement as BuildingElement sort AREA ASC WHERE contains(BuildingElement,[[Membrane]]) FLATTEN list(filter(file.lists, (x) => meta(x.section).subpath = "Issue Description").text) as SECTION ``` %% | Issue | Description | | --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | | [[3 Resources/Areas/Roof.md\|Roof]] \ [[3 Resources/Building Elements/Membrane.md\|Membrane]]<br><br>[[3 Resources/Issues/Waterproofing Osmosis Failure.md\|Waterproofing Osmosis Failure]] | <ul><li>many types of membrane are subject to Osmotic Failure.</li><li>This presents as blistering underneath the surface of the membrane.</li><li>For further information on the causes please see [OSMOTIC FAILURE](https://www.rdh.com/wp-content/uploads/2017/11/CCBST-2017-Solutions-Address-Osmosis-and-Blistering.pdf)</li></ul> | | [[3 Resources/Areas/Roof.md\|Roof]] \ [[3 Resources/Building Elements/Membrane.md\|Membrane]]<br><br>[[3 Resources/Issues/Waterproofing Penetration Plinths.md\|Waterproofing Penetration Plinths]] | <ul><li>Rooftop penetrations shall be raised up of Concrete decks with in-situ Concrete Plinths.</li><li>This greatly increases the efficacy of the waterproofing.</li><li>See [TOOLS](https://app.buildingtools.co/tools/waterproofing-external-roof-slab-penetrations?shareId=mnjaOC-1731389964752&menu_id=9-1-6-2) for a link to the image above.</li></ul> | | [[3 Resources/Areas/Everywhere.md\|Everywhere]] \ [[3 Resources/Building Elements/Membrane.md\|Membrane]]<br><br>[[3 Resources/Issues/Waterproofing Penetration Setout.md\|Waterproofing Penetration Setout]] | <ul><li>Services shall offset minimum 100mm other vertical services either walls or other service penetrations.</li><li>This gap is required to ensure there is space for wateproofing membranes can applied properly. There should be enough room for the largest of either the tool required to apply it or the puddle flange/service itself.</li></ul> | | [[3 Resources/Areas/Roof.md\|Roof]] \ [[3 Resources/Building Elements/Membrane.md\|Membrane]]<br><br>[[3 Resources/Issues/Waterproofing Services and Future Maintenance.md\|Waterproofing Services and Future Maintenance]] | <ul><li>Install Rooftop Membrane</li><li>Install Services in a hap hazard fashion.</li><li>If you are very lucky, add some touchup waterproofing will be done.</li><li>Plan out service installations carefully, ensuring they are neat on cable trays etc.</li><li>Provide the architect with a setout of all the service for review.</li><li>Install the services</li><li>Only after the service are installed, install the membrane.</li></ul> | %% DATAVIEW_PUBLISHER: end %%