# Mechanical
%% DATAVIEW_PUBLISHER: start
```
TABLE WITHOUT ID AREA, BuildingElement as Element,file.link as Issue,"☐ " + TASKS.text as Action
FROM "3 Resources/Issues"
FLATTEN file.tasks as TASKS
FLATTEN Areas as AREA
FLATTEN Disciplines as DISCIPLINE
sort AREA ASC
WHERE contains(DISCIPLINE,[[Mechanical]])
```
%%
| AREA | Element | Issue | Action |
| --------------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ---------------------------------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
| [[3 Resources/Areas/Basement.md\|Basement]] | <ul><li>[[3 Resources/Building Elements/Exhaust Ducts.md\|Exhaust Ducts]]</li></ul> | [[3 Resources/Issues/Coordinate Large Mechanical Ducts in the Basement.md\|Coordinate Large Mechanical Ducts in the Basement]] | ☐ Model all large exhaust ducts in 3D in the ArchiCAD Model so they are coordinated properly. |
| [[3 Resources/Areas/Basement.md\|Basement]] | <ul><li>[[3 Resources/Building Elements/Exhaust Ducts.md\|Exhaust Ducts]]</li></ul> | [[3 Resources/Issues/Coordinate Large Mechanical Ducts in the Basement.md\|Coordinate Large Mechanical Ducts in the Basement]] | ☐ Indicate these ducts on the Reflected Ceiling Plans |
| [[3 Resources/Areas/Basement.md\|Basement]] | <ul><li>[[3 Resources/Building Elements/Services.md\|Services]]</li></ul> | [[3 Resources/Issues/Impact Protection of Basement Services.md\|Impact Protection of Basement Services]] | ☐ Check that all services in the basement and ground floors are protected from traffic movements. Relocated them if it is not possible to use a bollard or barrier. |
| [[3 Resources/Areas/Basement.md\|Basement]] | <ul><li>[[3 Resources/Building Elements/Sprinkler Heads.md\|Sprinkler Heads]]</li></ul> | [[3 Resources/Issues/Sprinkler Heads Clash with Exhaust Ductwork.md\|Sprinkler Heads Clash with Exhaust Ductwork]] | ☐ Architect shall Indicate carpark and other large exhaust ducts on the RCPs |
| [[3 Resources/Areas/Basement.md\|Basement]] | <ul><li>[[3 Resources/Building Elements/Sprinkler Heads.md\|Sprinkler Heads]]</li></ul> | [[3 Resources/Issues/Sprinkler Heads Clash with Exhaust Ductwork.md\|Sprinkler Heads Clash with Exhaust Ductwork]] | ☐ Sprinkler designer shall check that area beneath exhaust ducts is adequately sprinklered. |
| [[3 Resources/Areas/Bathrooms.md\|Bathrooms]] | <ul><li>[[3 Resources/Building Elements/Bathroom Exhaust.md\|Bathroom Exhaust]]</li><li>[[3 Resources/Building Elements/Laundry Exhaust.md\|Laundry Exhaust]]</li><li>[[3 Resources/Building Elements/Fresh Air Supply.md\|Fresh Air Supply]]</li><li>[[3 Resources/Building Elements/Kitchen Exhaust.md\|Kitchen Exhaust]]</li></ul> | [[3 Resources/Issues/Add provision for constant ventilation.md\|Add provision for constant ventilation]] | ☐ Mechanical Engineer shall detail Filtered Supply air to all Apartments in accordance with [AS1668.2](https://au.i2.saiglobal.com/management/display/index/0/299720/-/4fb717692e783dfeeb6b566c7072d870) for both bathrooms and kitchen exhaust. |
| [[3 Resources/Areas/Bathrooms.md\|Bathrooms]] | <ul><li>[[3 Resources/Building Elements/Bathroom Exhaust.md\|Bathroom Exhaust]]</li><li>[[3 Resources/Building Elements/Laundry Exhaust.md\|Laundry Exhaust]]</li><li>[[3 Resources/Building Elements/Fresh Air Supply.md\|Fresh Air Supply]]</li><li>[[3 Resources/Building Elements/Kitchen Exhaust.md\|Kitchen Exhaust]]</li></ul> | [[3 Resources/Issues/Add provision for constant ventilation.md\|Add provision for constant ventilation]] | ☐ Mechanical Engineer Shal specify In-Line Fans with EC Motors, these are adjustable. |
| [[3 Resources/Areas/Bathrooms.md\|Bathrooms]] | <ul><li>[[3 Resources/Building Elements/Bathroom Exhaust.md\|Bathroom Exhaust]]</li><li>[[3 Resources/Building Elements/Laundry Exhaust.md\|Laundry Exhaust]]</li><li>[[3 Resources/Building Elements/Fresh Air Supply.md\|Fresh Air Supply]]</li><li>[[3 Resources/Building Elements/Kitchen Exhaust.md\|Kitchen Exhaust]]</li></ul> | [[3 Resources/Issues/Add provision for constant ventilation.md\|Add provision for constant ventilation]] | ☐ Mechanical Engineer shall specify 2 x speed speed controllers to the Fan Motors, allowing for a constant low volume level of exhaust. |
| [[3 Resources/Areas/Bathrooms.md\|Bathrooms]] | <ul><li>[[3 Resources/Building Elements/Bathroom Exhaust.md\|Bathroom Exhaust]]</li></ul> | [[3 Resources/Issues/Bathroom Exhaust Fan and Water Vapour.md\|Bathroom Exhaust Fan and Water Vapour]] | ☐ **Optimal Fan Placement:** Mechanical Engineer shall position the exhaust fan closer to the shower to capture and remove steam more efficiently. |
| [[3 Resources/Areas/Bathrooms.md\|Bathrooms]] | <ul><li>[[3 Resources/Building Elements/Bathroom Exhaust.md\|Bathroom Exhaust]]</li></ul> | [[3 Resources/Issues/Bathroom Exhaust Fan and Water Vapour.md\|Bathroom Exhaust Fan and Water Vapour]] | ☐ **Improve Airflow:** Builder shall provide additional relief air through a door grille, an undercut at the bottom of the bathroom door, or by keeping the door open when possible. |
| [[3 Resources/Areas/Bathrooms.md\|Bathrooms]] | <ul><li>[[3 Resources/Building Elements/Bathroom Exhaust.md\|Bathroom Exhaust]]</li></ul> | [[3 Resources/Issues/Bathroom Exhaust Fan and Water Vapour.md\|Bathroom Exhaust Fan and Water Vapour]] | ☐ **Regular Maintenance:** Customers should clean and maintain exhaust fans to prevent blockages and maintain peak performance. |
| [[3 Resources/Areas/Bathrooms.md\|Bathrooms]] | <ul><li>[[3 Resources/Building Elements/Bathroom Exhaust.md\|Bathroom Exhaust]]</li></ul> | [[3 Resources/Issues/Bathroom Exhaust Fan and Water Vapour.md\|Bathroom Exhaust Fan and Water Vapour]] | ☐ **Use Moisture-Resistant Finishes:** Architect shall select mold-resistant paint, tiles, and materials to mitigate the impact of lingering condensation. For example - [Zinsser](https://www.rustoleum.com.au/product-catalog/consumer-brands/zinsser) paints should be specified for use in the bathroom areas |
| [[3 Resources/Areas/Bathrooms.md\|Bathrooms]] | <ul><li>[[3 Resources/Building Elements/Exhaust Ducts.md\|Exhaust Ducts]]</li></ul> | [[3 Resources/Issues/Excessive use of Flexible Ducitng leads to Poor Exhaust Systems.md\|Excessive use of Flexible Ducitng leads to Poor Exhaust Systems]] | ☐ Mechanical Engineer design and exhaust and AC systems so at most 1.5m lengths of flexible ducting are used. |
| [[3 Resources/Areas/Bedrooms.md\|Bedrooms]] | <ul><li>[[3 Resources/Building Elements/Air Conditioning.md\|Air Conditioning]]</li></ul> | [[3 Resources/Issues/Condensate Lines Need to Be Accessible.md\|Condensate Lines Need to Be Accessible]] | ☐ Mechanical Engineer shall check that there are adequate tundishes to drain each air-conditioning unit. |
| [[3 Resources/Areas/Bedrooms.md\|Bedrooms]] | <ul><li>[[3 Resources/Building Elements/Air Conditioning.md\|Air Conditioning]]</li></ul> | [[3 Resources/Issues/Condensate Lines Need to Be Accessible.md\|Condensate Lines Need to Be Accessible]] | ☐ Architect shall coordinate with the Mechanical Engineer to ensure all AC units are drained. |
| [[3 Resources/Areas/Bedrooms.md\|Bedrooms]] | <ul><li>[[3 Resources/Building Elements/Access Panels.md\|Access Panels]]</li></ul> | [[3 Resources/Issues/Insufficient Access Panels for Mechanical Servicing.md\|Insufficient Access Panels for Mechanical Servicing]] | ☐ Mechanical Engineer shall indicate all required access panels for each Fan Coil Unit on the mechanical Drawings. |
| [[3 Resources/Areas/Bedrooms.md\|Bedrooms]] | <ul><li>[[3 Resources/Building Elements/Access Panels.md\|Access Panels]]</li></ul> | [[3 Resources/Issues/Insufficient Access Panels for Mechanical Servicing.md\|Insufficient Access Panels for Mechanical Servicing]] | ☐ The Architect shall document the location of these Access Panels on the RCPs. |
| [[3 Resources/Areas/Bedrooms.md\|Bedrooms]] | <ul><li>[[3 Resources/Building Elements/Access Panels.md\|Access Panels]]</li></ul> | [[3 Resources/Issues/Insufficient Access Panels for Mechanical Servicing.md\|Insufficient Access Panels for Mechanical Servicing]] | ☐ The Director of the Mechanical contracting company shall provide a personal guarantee that all Fan Coil Units are capable of being serviced prior to Occupation. |
| [[3 Resources/Areas/Everywhere.md\|Everywhere]] | <ul><li>[[3 Resources/Building Elements/Exhaust Ducts.md\|Exhaust Ducts]]</li></ul> | [[3 Resources/Issues/Coordinate Large Mechanical Ducts in the Basement.md\|Coordinate Large Mechanical Ducts in the Basement]] | ☐ Model all large exhaust ducts in 3D in the ArchiCAD Model so they are coordinated properly. |
| [[3 Resources/Areas/Everywhere.md\|Everywhere]] | <ul><li>[[3 Resources/Building Elements/Exhaust Ducts.md\|Exhaust Ducts]]</li></ul> | [[3 Resources/Issues/Coordinate Large Mechanical Ducts in the Basement.md\|Coordinate Large Mechanical Ducts in the Basement]] | ☐ Indicate these ducts on the Reflected Ceiling Plans |
| [[3 Resources/Areas/Everywhere.md\|Everywhere]] | <ul><li>[[3 Resources/Building Elements/Air Conditioning.md\|Air Conditioning]]</li></ul> | [[3 Resources/Issues/Pair Coil Insulation Material.md\|Pair Coil Insulation Material]] | ☐ Mechanical contractor shall provide AS1530.3 test certificates for Pair coil insulation used to the certifier prior to installation. |
| [[3 Resources/Areas/Everywhere.md\|Everywhere]] | <ul><li>[[3 Resources/Building Elements/Internal Walls.md\|Internal Walls]]</li><li>[[3 Resources/Building Elements/Services.md\|Services]]</li></ul> | [[3 Resources/Issues/Passive Fire Documentation.md\|Passive Fire Documentation]] | ☐ Builder and Sub-contractors shall familiarize themselves with AS4072. |
| [[3 Resources/Areas/Everywhere.md\|Everywhere]] | <ul><li>[[3 Resources/Building Elements/Internal Walls.md\|Internal Walls]]</li><li>[[3 Resources/Building Elements/Services.md\|Services]]</li></ul> | [[3 Resources/Issues/Passive Fire Documentation.md\|Passive Fire Documentation]] | ☐ Builder shall provide one complete Passive Fire Register on Completion that complies with AS4072 |
| [[3 Resources/Areas/Everywhere.md\|Everywhere]] | <ul><li>[[3 Resources/Building Elements/Service Cupboards.md\|Service Cupboards]]</li></ul> | [[3 Resources/Issues/Service Riser Coordination.md\|Service Riser Coordination]] | ☐ Architect to check that no wet areas are located above any service cupboards. |
| [[3 Resources/Areas/Everywhere.md\|Everywhere]] | <ul><li>[[3 Resources/Building Elements/Service Cupboards.md\|Service Cupboards]]</li></ul> | [[3 Resources/Issues/Service Riser Coordination.md\|Service Riser Coordination]] | ☐ Architect to check that all service cupboards and risers are vertically aligned throughout the building. |
| [[3 Resources/Areas/Everywhere.md\|Everywhere]] | <ul><li>[[3 Resources/Building Elements/Services.md\|Services]]</li><li>[[3 Resources/Building Elements/Fire Stairs.md\|Fire Stairs]]</li><li>[[3 Resources/Building Elements/Fire Exit.md\|Fire Exit]]</li></ul> | [[3 Resources/Issues/Services in Fire Stairs and Exits.md\|Services in Fire Stairs and Exits]] | ☐ Architect shall check that no services (other than those related to the fire system) are located in fire stairs. |
| [[3 Resources/Areas/Everywhere.md\|Everywhere]] | <ul><li>[[3 Resources/Building Elements/Services.md\|Services]]</li><li>[[3 Resources/Building Elements/Fire Stairs.md\|Fire Stairs]]</li><li>[[3 Resources/Building Elements/Fire Exit.md\|Fire Exit]]</li></ul> | [[3 Resources/Issues/Services in Fire Stairs and Exits.md\|Services in Fire Stairs and Exits]] | ☐ Hydraulic Engineer shall check that no services (other than those related to the fire system) are located in fire stairs. |
| [[3 Resources/Areas/Everywhere.md\|Everywhere]] | <ul><li>[[3 Resources/Building Elements/Services.md\|Services]]</li><li>[[3 Resources/Building Elements/Fire Stairs.md\|Fire Stairs]]</li><li>[[3 Resources/Building Elements/Fire Exit.md\|Fire Exit]]</li></ul> | [[3 Resources/Issues/Services in Fire Stairs and Exits.md\|Services in Fire Stairs and Exits]] | ☐ Electrical Engineer shall check that no services (other than those related to the fire system) are located in fire stairs. |
| [[3 Resources/Areas/Everywhere.md\|Everywhere]] | <ul><li>[[3 Resources/Building Elements/Services.md\|Services]]</li><li>[[3 Resources/Building Elements/Fire Stairs.md\|Fire Stairs]]</li><li>[[3 Resources/Building Elements/Fire Exit.md\|Fire Exit]]</li></ul> | [[3 Resources/Issues/Services in Fire Stairs and Exits.md\|Services in Fire Stairs and Exits]] | ☐ Mechanical Engineer shall check that no services (other than those related to the fire system) are located in fire stairs. |
| [[3 Resources/Areas/Everywhere.md\|Everywhere]] | <ul><li>[[3 Resources/Disciplines/Passive Fire.md\|Passive Fire]]</li><li>[[3 Resources/Building Elements/Fire Compartmentation.md\|Fire Compartmentation]]</li><li>[[3 Resources/Building Elements/Services.md\|Services]]</li></ul> | [[3 Resources/Issues/Services Installed Before Walls.md\|Services Installed Before Walls]] | ☐ Builder shall ensure that all walls are installed before services installation commences. |
| [[3 Resources/Areas/Everywhere.md\|Everywhere]] | <ul><li>[[3 Resources/Building Elements/Membrane.md\|Membrane]]</li></ul> | [[3 Resources/Issues/Waterproofing Penetration Setout.md\|Waterproofing Penetration Setout]] | ☐ Architect to check that all service penetrations have minimum 100mm clearance from other vertical faces. |
| [[3 Resources/Areas/Everywhere.md\|Everywhere]] | <ul><li>[[3 Resources/Building Elements/Membrane.md\|Membrane]]</li></ul> | [[3 Resources/Issues/Waterproofing Penetration Setout.md\|Waterproofing Penetration Setout]] | ☐ Service Engineers to detail at 1:20 areas that are clustered with multiple penetrations like service cupboard risers. |
| [[3 Resources/Areas/Ground Floor.md\|Ground Floor]] | <ul><li>[[3 Resources/Building Elements/Services.md\|Services]]</li></ul> | [[3 Resources/Issues/Impact Protection of Basement Services.md\|Impact Protection of Basement Services]] | ☐ Check that all services in the basement and ground floors are protected from traffic movements. Relocated them if it is not possible to use a bollard or barrier. |
| [[3 Resources/Areas/Kitchens.md\|Kitchens]] | <ul><li>[[3 Resources/Building Elements/Bathroom Exhaust.md\|Bathroom Exhaust]]</li><li>[[3 Resources/Building Elements/Laundry Exhaust.md\|Laundry Exhaust]]</li><li>[[3 Resources/Building Elements/Fresh Air Supply.md\|Fresh Air Supply]]</li><li>[[3 Resources/Building Elements/Kitchen Exhaust.md\|Kitchen Exhaust]]</li></ul> | [[3 Resources/Issues/Add provision for constant ventilation.md\|Add provision for constant ventilation]] | ☐ Mechanical Engineer shall detail Filtered Supply air to all Apartments in accordance with [AS1668.2](https://au.i2.saiglobal.com/management/display/index/0/299720/-/4fb717692e783dfeeb6b566c7072d870) for both bathrooms and kitchen exhaust. |
| [[3 Resources/Areas/Kitchens.md\|Kitchens]] | <ul><li>[[3 Resources/Building Elements/Bathroom Exhaust.md\|Bathroom Exhaust]]</li><li>[[3 Resources/Building Elements/Laundry Exhaust.md\|Laundry Exhaust]]</li><li>[[3 Resources/Building Elements/Fresh Air Supply.md\|Fresh Air Supply]]</li><li>[[3 Resources/Building Elements/Kitchen Exhaust.md\|Kitchen Exhaust]]</li></ul> | [[3 Resources/Issues/Add provision for constant ventilation.md\|Add provision for constant ventilation]] | ☐ Mechanical Engineer Shal specify In-Line Fans with EC Motors, these are adjustable. |
| [[3 Resources/Areas/Kitchens.md\|Kitchens]] | <ul><li>[[3 Resources/Building Elements/Bathroom Exhaust.md\|Bathroom Exhaust]]</li><li>[[3 Resources/Building Elements/Laundry Exhaust.md\|Laundry Exhaust]]</li><li>[[3 Resources/Building Elements/Fresh Air Supply.md\|Fresh Air Supply]]</li><li>[[3 Resources/Building Elements/Kitchen Exhaust.md\|Kitchen Exhaust]]</li></ul> | [[3 Resources/Issues/Add provision for constant ventilation.md\|Add provision for constant ventilation]] | ☐ Mechanical Engineer shall specify 2 x speed speed controllers to the Fan Motors, allowing for a constant low volume level of exhaust. |
| [[3 Resources/Areas/Laundry.md\|Laundry]] | <ul><li>[[3 Resources/Building Elements/Bathroom Exhaust.md\|Bathroom Exhaust]]</li><li>[[3 Resources/Building Elements/Laundry Exhaust.md\|Laundry Exhaust]]</li><li>[[3 Resources/Building Elements/Fresh Air Supply.md\|Fresh Air Supply]]</li><li>[[3 Resources/Building Elements/Kitchen Exhaust.md\|Kitchen Exhaust]]</li></ul> | [[3 Resources/Issues/Add provision for constant ventilation.md\|Add provision for constant ventilation]] | ☐ Mechanical Engineer shall detail Filtered Supply air to all Apartments in accordance with [AS1668.2](https://au.i2.saiglobal.com/management/display/index/0/299720/-/4fb717692e783dfeeb6b566c7072d870) for both bathrooms and kitchen exhaust. |
| [[3 Resources/Areas/Laundry.md\|Laundry]] | <ul><li>[[3 Resources/Building Elements/Bathroom Exhaust.md\|Bathroom Exhaust]]</li><li>[[3 Resources/Building Elements/Laundry Exhaust.md\|Laundry Exhaust]]</li><li>[[3 Resources/Building Elements/Fresh Air Supply.md\|Fresh Air Supply]]</li><li>[[3 Resources/Building Elements/Kitchen Exhaust.md\|Kitchen Exhaust]]</li></ul> | [[3 Resources/Issues/Add provision for constant ventilation.md\|Add provision for constant ventilation]] | ☐ Mechanical Engineer Shal specify In-Line Fans with EC Motors, these are adjustable. |
| [[3 Resources/Areas/Laundry.md\|Laundry]] | <ul><li>[[3 Resources/Building Elements/Bathroom Exhaust.md\|Bathroom Exhaust]]</li><li>[[3 Resources/Building Elements/Laundry Exhaust.md\|Laundry Exhaust]]</li><li>[[3 Resources/Building Elements/Fresh Air Supply.md\|Fresh Air Supply]]</li><li>[[3 Resources/Building Elements/Kitchen Exhaust.md\|Kitchen Exhaust]]</li></ul> | [[3 Resources/Issues/Add provision for constant ventilation.md\|Add provision for constant ventilation]] | ☐ Mechanical Engineer shall specify 2 x speed speed controllers to the Fan Motors, allowing for a constant low volume level of exhaust. |
| [[3 Resources/Areas/Laundry.md\|Laundry]] | <ul><li>[[3 Resources/Building Elements/Air Conditioning.md\|Air Conditioning]]</li></ul> | [[3 Resources/Issues/Condensate Lines Need to Be Accessible.md\|Condensate Lines Need to Be Accessible]] | ☐ Mechanical Engineer shall check that there are adequate tundishes to drain each air-conditioning unit. |
| [[3 Resources/Areas/Laundry.md\|Laundry]] | <ul><li>[[3 Resources/Building Elements/Air Conditioning.md\|Air Conditioning]]</li></ul> | [[3 Resources/Issues/Condensate Lines Need to Be Accessible.md\|Condensate Lines Need to Be Accessible]] | ☐ Architect shall coordinate with the Mechanical Engineer to ensure all AC units are drained. |
| [[3 Resources/Areas/Laundry.md\|Laundry]] | <ul><li>[[3 Resources/Building Elements/Exhaust Ducts.md\|Exhaust Ducts]]</li></ul> | [[3 Resources/Issues/Excessive use of Flexible Ducitng leads to Poor Exhaust Systems.md\|Excessive use of Flexible Ducitng leads to Poor Exhaust Systems]] | ☐ Mechanical Engineer design and exhaust and AC systems so at most 1.5m lengths of flexible ducting are used. |
| [[3 Resources/Areas/Laundry.md\|Laundry]] | <ul><li>[[3 Resources/Building Elements/Laundry Exhaust.md\|Laundry Exhaust]]</li></ul> | [[3 Resources/Issues/Poor Laundry Exhaust.md\|Poor Laundry Exhaust]] | ☐ Check that Laundry Fan is interlocked with PowerPoints for washing machines and driers. |
| [[3 Resources/Areas/Living Areas.md\|Living Areas]] | <ul><li>[[3 Resources/Building Elements/Bathroom Exhaust.md\|Bathroom Exhaust]]</li><li>[[3 Resources/Building Elements/Laundry Exhaust.md\|Laundry Exhaust]]</li><li>[[3 Resources/Building Elements/Fresh Air Supply.md\|Fresh Air Supply]]</li><li>[[3 Resources/Building Elements/Kitchen Exhaust.md\|Kitchen Exhaust]]</li></ul> | [[3 Resources/Issues/Add provision for constant ventilation.md\|Add provision for constant ventilation]] | ☐ Mechanical Engineer shall detail Filtered Supply air to all Apartments in accordance with [AS1668.2](https://au.i2.saiglobal.com/management/display/index/0/299720/-/4fb717692e783dfeeb6b566c7072d870) for both bathrooms and kitchen exhaust. |
| [[3 Resources/Areas/Living Areas.md\|Living Areas]] | <ul><li>[[3 Resources/Building Elements/Bathroom Exhaust.md\|Bathroom Exhaust]]</li><li>[[3 Resources/Building Elements/Laundry Exhaust.md\|Laundry Exhaust]]</li><li>[[3 Resources/Building Elements/Fresh Air Supply.md\|Fresh Air Supply]]</li><li>[[3 Resources/Building Elements/Kitchen Exhaust.md\|Kitchen Exhaust]]</li></ul> | [[3 Resources/Issues/Add provision for constant ventilation.md\|Add provision for constant ventilation]] | ☐ Mechanical Engineer Shal specify In-Line Fans with EC Motors, these are adjustable. |
| [[3 Resources/Areas/Living Areas.md\|Living Areas]] | <ul><li>[[3 Resources/Building Elements/Bathroom Exhaust.md\|Bathroom Exhaust]]</li><li>[[3 Resources/Building Elements/Laundry Exhaust.md\|Laundry Exhaust]]</li><li>[[3 Resources/Building Elements/Fresh Air Supply.md\|Fresh Air Supply]]</li><li>[[3 Resources/Building Elements/Kitchen Exhaust.md\|Kitchen Exhaust]]</li></ul> | [[3 Resources/Issues/Add provision for constant ventilation.md\|Add provision for constant ventilation]] | ☐ Mechanical Engineer shall specify 2 x speed speed controllers to the Fan Motors, allowing for a constant low volume level of exhaust. |
| [[3 Resources/Areas/Living Areas.md\|Living Areas]] | <ul><li>[[3 Resources/Building Elements/Air Conditioning.md\|Air Conditioning]]</li></ul> | [[3 Resources/Issues/Condensate Lines Need to Be Accessible.md\|Condensate Lines Need to Be Accessible]] | ☐ Mechanical Engineer shall check that there are adequate tundishes to drain each air-conditioning unit. |
| [[3 Resources/Areas/Living Areas.md\|Living Areas]] | <ul><li>[[3 Resources/Building Elements/Air Conditioning.md\|Air Conditioning]]</li></ul> | [[3 Resources/Issues/Condensate Lines Need to Be Accessible.md\|Condensate Lines Need to Be Accessible]] | ☐ Architect shall coordinate with the Mechanical Engineer to ensure all AC units are drained. |
| [[3 Resources/Areas/Living Areas.md\|Living Areas]] | <ul><li>[[3 Resources/Building Elements/Access Panels.md\|Access Panels]]</li></ul> | [[3 Resources/Issues/Insufficient Access Panels for Mechanical Servicing.md\|Insufficient Access Panels for Mechanical Servicing]] | ☐ Mechanical Engineer shall indicate all required access panels for each Fan Coil Unit on the mechanical Drawings. |
| [[3 Resources/Areas/Living Areas.md\|Living Areas]] | <ul><li>[[3 Resources/Building Elements/Access Panels.md\|Access Panels]]</li></ul> | [[3 Resources/Issues/Insufficient Access Panels for Mechanical Servicing.md\|Insufficient Access Panels for Mechanical Servicing]] | ☐ The Architect shall document the location of these Access Panels on the RCPs. |
| [[3 Resources/Areas/Living Areas.md\|Living Areas]] | <ul><li>[[3 Resources/Building Elements/Access Panels.md\|Access Panels]]</li></ul> | [[3 Resources/Issues/Insufficient Access Panels for Mechanical Servicing.md\|Insufficient Access Panels for Mechanical Servicing]] | ☐ The Director of the Mechanical contracting company shall provide a personal guarantee that all Fan Coil Units are capable of being serviced prior to Occupation. |
| [[3 Resources/Areas/Living Areas.md\|Living Areas]] | <ul><li>[[3 Resources/Building Elements/Air Conditioning.md\|Air Conditioning]]</li></ul> | [[3 Resources/Issues/Return-Air Ducted through the ceiling.md\|Return-Air Ducted through the ceiling]] | ☐ The Mechanical engineer shall check the return air pathways for all AC units are not prone to sucking air from the wrong space. |
| [[3 Resources/Areas/Lobbies.md\|Lobbies]] | <ul><li>[[3 Resources/Building Elements/Service Cupboards.md\|Service Cupboards]]</li></ul> | [[3 Resources/Issues/Congested Riser Cupboards.md\|Congested Riser Cupboards]] | ☐ Service Consultants shall prepare 1:20 drawings of each floor's service cupboards and nominate and depict the fire-stopping methods on those drawings and any associated meters. |
| [[3 Resources/Areas/Lobbies.md\|Lobbies]] | <ul><li>[[3 Resources/Building Elements/Service Cupboards.md\|Service Cupboards]]</li></ul> | [[3 Resources/Issues/Congested Riser Cupboards.md\|Congested Riser Cupboards]] | ☐ Architect shall prepare standard service cupboards for all services including Water, Electrical, Mechanical and Fire |
| [[3 Resources/Areas/Roof.md\|Roof]] | <ul><li>[[3 Resources/Building Elements/Air Conditioning.md\|Air Conditioning]]</li></ul> | [[3 Resources/Issues/Vibration from Condenser Units.md\|Vibration from Condenser Units]] | ☐ Acoustic Engineer shall specify NRD, Waffle Pads or Supershearflex mounts for the each type of Air Conditioning Condenser Unit in a building. |
| [[3 Resources/Areas/Roof.md\|Roof]] | <ul><li>[[3 Resources/Building Elements/Air Conditioning.md\|Air Conditioning]]</li></ul> | [[3 Resources/Issues/Vibration from Condenser Units.md\|Vibration from Condenser Units]] | ☐ Mechanical Engineer shall specify NRD, Waffle Pads or Supershearflex mounts for the each type of Air Conditioning Condenser Unit in a building., |
| [[3 Resources/Areas/Wet Areas.md\|Wet Areas]] | <ul><li>[[3 Resources/Building Elements/Bathroom Exhaust.md\|Bathroom Exhaust]]</li></ul> | [[3 Resources/Issues/Bathroom Exhaust Fan Performance.md\|Bathroom Exhaust Fan Performance]] | ☐ Mechanical Engineer shall specify Inline Fans. |
| [[3 Resources/Areas/Wet Areas.md\|Wet Areas]] | <ul><li>[[3 Resources/Building Elements/Bathroom Exhaust.md\|Bathroom Exhaust]]</li></ul> | [[3 Resources/Issues/Bathroom Exhaust Fan Performance.md\|Bathroom Exhaust Fan Performance]] | ☐ Mechanical Engineer shall locate bathroom exhaust fans as close the the shower as possible. |
| [[3 Resources/Areas/Wet Areas.md\|Wet Areas]] | <ul><li>[[3 Resources/Building Elements/Bathroom Exhaust.md\|Bathroom Exhaust]]</li></ul> | [[3 Resources/Issues/Bathroom Exhaust Fan Performance.md\|Bathroom Exhaust Fan Performance]] | ☐ Architect shall locate the exhaust fans as close to the shower as possible. |
%% DATAVIEW_PUBLISHER: end %%